Out-of-plane seismic performance of plasterboard partition walls via quasi-static tests
DOI:
https://doi.org/10.5459/bnzsee.49.1.125-137Abstract
Internal partitions, as many nonstructural components, should be subjected to a careful and rational seismic design, as is done for structural elements. A quasi-static test campaign aimed at the evaluation of the out-of-plane seismic performance of Siniat plasterboard internal partitions with steel studs was conducted according to FEMA 461 testing protocol. Four tall, i.e. 5 m high, specimens were selected from the range of internal partitions developed in Europe by Siniat, a leading supplier of plasterboard components in Europe.
Under the specified testing protocol, a significant nonlinear pinched behaviour of the tested specimen was observed. The pinched behaviour was caused by the damage in the screwed connections, whose cyclic behaviour was strongly degrading. Both stiffness and strength of the specimens are significantly influenced by the board typology and the amount of screwed connections. Finally, it was concluded that Eurocodes significantly underestimate the resisting bending moment of the tested specimens.
References
Bertero RD and Bertero VV (2002). "Performance-Based Seismic Engineering: The Need for a Reliable Conceptual Comprehensive Approach". Earthquake Engineering & Structural Dynamics, 31(3): 627-652. DOI: https://doi.org/10.1002/eqe.146
Taghavi S and Miranda E (2003). "Response Assessment of Nonstructural Building Elements”. PEER Report 2003/05, College of Engineering, University of California Berkeley, USA.
Ikuta E and Miyano M (2011). "Study of Damage to the Human Body Caused by Earthquakes: Development of a Mannequin for Thoracic Compression Experiments and Cyber Mannequin Using the Finite Element Method". In: R. Spence, E. So, C. Scawthorn, editors. Human Casualties in Earthquakes: Springer Netherlands. p. 275-289.
Villaverde R (1997). "Seismic Design of Secondary Structures: State of the Art". Journal of Structural Engineering-ASCE, 123(8): 1011-1019. DOI: https://doi.org/10.1061/(ASCE)0733-9445(1997)123:8(1011)
Lee TH, Kato M, Matsumiya T, Suita K and Nakashima M (2007). "Seismic Performance Evaluation of Non-Structural Components: Drywall Partitions". Earthquake Engineering & Structural Dynamics, 36(3): 367-382. DOI: https://doi.org/10.1002/eqe.638
Restrepo JI and Lang AF (2011). "Study of Loading Protocols in Light-Gauge Stud Partition Walls". Earthquake Spectra, 27(4): 1169-1185. DOI: https://doi.org/10.1193/1.3651608
Restrepo JI and Bersofsky AM (2011). "Performance Characteristics of Light Gage Steel Stud Partition Walls". Thin-Walled Structures, 49(2): 317-324. DOI: https://doi.org/10.1016/j.tws.2010.10.001
Tasligedik AS, Pampanin S and Palermo A (2012). "Damage States and Cyclic Behaviour of Drywalls Infilled within RC Frames". Bulletin of the New Zealand Society for Earthquake Engineering, 45(2): 84-94. DOI: https://doi.org/10.5459/bnzsee.45.2.84-94
Magliulo G, Petrone C, Capozzi V, Maddaloni G, Lopez P, Talamonti R and Manfredi G (2012). "Shake Table Tests on Infill Plasterboard Partitions". The Open Construction and Building Technology Journal, 6 (Suppl 1-M10): 155-163.
Retamales R, Davies R, Mosqueda G and Filiatrault A (2013). "Experimental Seismic Fragility of Cold-Formed Steel Framed Gypsum Partition Walls". Journal of Structural Engineering, 139(8): 1285-1293. DOI: https://doi.org/10.1061/(ASCE)ST.1943-541X.0000657
Davies R, Retamales R, Mosqueda G and Filiatrault A (2011). "Experimental Seismic Evaluation, Model Parameterization, and Effects of Cold-Formed Steel-Framed Gypsum Partition Walls on the Seismic Performance of an Essential Facility”. Technical Report MCEER-11-0005, University at Buffalo, State University of New York.
Magliulo G, Petrone C, Capozzi V, Maddaloni G, Lopez P and Manfredi G (2014). "Seismic Performance Evaluation of Plasterboard Partitions via Shake Table Tests". Bulletin of Earthquake Engineering, 12(4): 1657-1677. DOI: https://doi.org/10.1007/s10518-013-9567-8
International Conference of Building Officials (ICBO) (2000). "AC 156 Acceptance Criteria for the Seismic Qualification of Nonstructural Components". ICBO Evaluation Service, Inc., Whittier, California, USA.
CEN (2004). "Eurocode 8: Design of Structures for Earthquake Resistance - Part 1: General Rules, Seismic Actions and Rules for Buildings. EN 1998-1". Brussels, Belgium.
Peterman K and Schafer B (2014). "Sheathed Cold-Formed Steel Studs under Axial and Lateral Load". Journal of Structural Engineering, 140(10): 04014074.
ASTM (2015). "Standard Test Methods of Conducting Strength Tests of Panels for Building Construction. ASTM E72-15". ASTM: West Conshohocken, PA.
FEMA 461 (2007). "Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components". Redwood City, California, USA.
Petrone C, Magliulo G, Lopez P and Manfredi G (2015). "Seismic Fragility Evaluation of Plasterboard Partitions via In-Plane Quasi-Static Tests". Earthquake Engineering & Structural Dynamics, 44(14): 2589-2606. DOI: https://doi.org/10.1002/eqe.2600
Petrone C, Magliulo G and Manfredi G (2015). "Floor Response Spectra in RC Frame Structures Designed According to Eurocode 8". Bulletin of Earthquake Engineering, (online early).
Petrone C, Magliulo G and Manfredi G (2015). "Seismic Demand on Light Acceleration-Sensitive Nonstructural Components in European Reinforced Concrete Buildings". Earthquake Engineering & Structural Dynamics, 44(8): 1203-1217. DOI: https://doi.org/10.1002/eqe.2508
CEN (2004). "Eurocode 3: Design of Steel Structures - Part 1-3: Supplementary Rules for Cold-Formed Members and Sheeting. EN 1993-1-3". Brussels, Belgium.